Injection Molding – Small Plastic Parts – Problem and Solution
The Problem:
A manufacturer of small plastic injection molded parts (caps, closures, fitments and pipettes) was experiencing static electricity problems during various steps in their molding and handling operations.
The Solution:
Because there were two different areas needing static control, we recommended a multifaceted approach using two different types of static control – the Super Air-Knife at the mold cycle and the Vortex Blower on the conveyors.